R value: R8.3. Thickness: 2-1/4 in. Width: .

3M Fire Barrier Duct Wrap 15A is an ideal fire resistive enclosure for commercial kitchen grease ducts. It is a proven performance alternative to a. or 2 hour fire resistant rated shaft enclosures and provides zero clearance to combustible construction at overlap or collar. 3M Fire Barrier 1000 N/S, 1003 S/L or 2000+ Silicone Sealant is used in ...Dec 3, 2016 · In this type of application, a material with a good STC rating (such as a closed cell insulation or a mass loaded elastomer or vinyl) can reduce the noise to acceptable levels. But unlike sound absorption, where the duct is lined, sound transmission can be controlled through the use of duct lining or duct wrap. Looking at Indoor Air QualityProduct Name Duct Wrap LF Synonyms Duct wrap, SoftR, duct wrap, duct insulation Product Code OCIS00044 Recommended Use Duct insulation Company Phone Number 1-800-GET-PINK or 1-800-438-7465 24 Hour Emergency Phone Number Chemtrec 1-800-424-9300 or 1-703-741-5970 CCN17393 Emergency Telephone 1-419-248-5330 (after 5 pm ET and weekends)Duct Wrap XL Roll 1-1/2" x 24" x 25' 1 37.5 lbs. Duct Wrap XL Roll 1-1/2" x 48" x 25' 1 75 lbs. Duct Wrap XL CollarRoll 1-1/2" x 6" x 25' 4 37.5 lbs. Color White blanket with silver foil encapsulation Reference Standard Standard No. Performance Grease Duct Enclosure SystemASTM E2336 Pass Section 16.1 - Non-Combustibility ASTM E136 PassJohns Manville’s Microlite® Vinyl duct wrap is a thermal insulation made from flame attenuated glass fibers. It is made with a phenolic binder and laminated onto a white, vinyl facing. Microlite Vinyl delivers a high tensile strength core for improved handling and easy installation. R Value: 3.9 (1.5") Permeance Rating: 1.3 perms. Available ...HVAC Insulation. At Johns Manville, we are committed to delivering the industry's most complete line of HVAC insulation for both commercial and residential buildings. We are the market leader in HVAC insulation, and have a 50-year history of providing duct liner, duct board and duct wrap solutions with superior consistency and quality.Atmosphere Duct Wrap is a thermal and acoustical insulation blanket made from highly resilient, inorganic fiberglass bonded by ECOSE Technology. It is available unfaced, with a foil-scrim-kraft (FSK) jacket and with a white metalized polypropylene-scrim …Insulates duct pipe up to 4 in. Dia and up to 5 ft. L. R-6 value for effective insulation of your duct system. Reduces mold-causing condensation and absorbs draft and duct system noise. Meets ASTM E84-20 surface burn standard. Tested by an accredited third-party laboratory.(4°C) and 250°F (121°C). When installed over sealed sheet metal ducts, duct wrap insulation ... depending on product type, thick- ness, and ... duct wrap insulation ...thermal resistance of R-4.2 and R-6.0. All products within this line are classified as Class 1/Class A in accordance with the ASTM E84-09 fire test ... (R-4.2) - Duct Insulation with bubble spacers (R-6.0) TECHNICAL DATA SHEET T E C H N I C A L D A T A PATENTS US Patent No.: 7,935,410 US Patent No.: 7,935,411Depending on the HVAC system and the type of insulation used, it is estimated that insulated HVAC ductwork can last anywhere from 10 to 30 years before needing to be replaced or repaired. Insulapack is a leading manufaturer of HVAC duct insulation wrap with higher quality and better-insulating.... type insulation with multiple uses. The Duct-Wrap offers excellent thermal and acoustical performance and carries a Class-A Fire rating. Made from durable ...Type I, Type 75 Duct Wrap Type II, Type 100 & 150 Duct Wrap Type III, Type 150 Duct Wrap - CAN/CGSB-51.11-92 - ASTM C1136: FSK & White PSK, Type II, Gray PSK, Type IV • Fire Safety Standards: - NFPA 90A, NFPA 90B Fire Resistance • Fire Hazard Classification: - UL 723, ASTM E84, CAN/ULC-S102 Max. Flame Spread Index: 25 Max.Atmosphere Duct Wrap - Transparency CatalogJohns Manville Duct Wrap, Fbrgls 1-1/2"x48"x100' R4.2 FSK SKU: MIDW1.5 MFG Part Number: MIDW1.5IV. After clips are installed, cut off or bend flush with insulation (Item 3) pins that are too long. B. Butt Joint with Collar: Locate pins at all blanket overlaps, on all sides of the ventilation duct (Item 1), and meet the following requirements. I. Space pins maximum 12 inches apart in rows across the width of the ventilation duct (Item 1). Locate pins …Thin, lightweight and flexible, 3M™ Fire Barrier Duct Wrap 615 provides excellent insulating capabilities and is a space-saving alternative to traditional, fire-rated gypsum shaft enclosures. It provides up to two-hour fire-resistance ratings for air distribution duct systems, meeting code and fire protection requirements.Fire-rated duct wrap consisting of an inorganic fiber blanket encapsulated with a scrim-reinforced foil; Blanket is adhered to the foil scrim it will resist wrapping and slumping ; Third party certified to ASTM E2336 (grease duct test standard) and ISO 6944 (air duct test standard) Tested and listed with UL and intertek, meets IBC, IMC, UMN, NFPA and …For ventilation air ducts, provide one layer of 3M Fire Barrier Duct Wrap 615+ with 3 inch (76 mm) overlaps for 1 and 2 hour applications. Observe requirements for additional duct wrap material required at firestop, when required. Ventilation Ductwork (1 and 2 hr. applications): overlap perimeter and longitudinal joints 3 inches (76 mm).Faced Duct Wrap Insulation complies with the property requirements of the following specifications: • U.S. Federal Specification HH-I-558 B, Form B, Type 1, Class 6, • ASTM C 553 • DCL ASTM - C 533 - C 547 - C 612 - C 665 • CE-EN 13162 Fire Properties B.S. 476 PART 4 - Non CombustibleId: C1136 Type: II Id: C1290 Type: III Id: C553 Type: II (SOFTR Duct Wrap FRK Types 100 and 150) Id: C553 Type: I (Fiberglas™ Duct Wrap Type 75) Manufacturer. Owens ...Type I, Type II Type 75 & 100 Type I, Type II, Type III Type 150 *For faced material: 250°F (121°C) maximum temperature. ASTM C1136s† Type II FSK Facing †Replaces HH-B-100B, Type II. Canada: CGSB 51-GP-11M NYC MEA 40-75-M 25 50 HVAC INSULATION MICROLITE® FSK FSK-FACED FORMALDEHYDE-FREE TM FIBERGLASS DUCT WRAP DATA SHEETThe duct enclosure system shall be listed by Intertek per ASTM E2336, CAN/ULC S144 and CAN/ULC S115 for a 2-hour rating and zero clearance to combustibles and tested per ASTM E84 or UL 723 for a flame/ smoke rating less than 25/50. Insulation shall have a nominal thickness of 1.5" (38mm) and density of 4.4 pcf (70kg/m3). ®Type 475 125 914 864 25 mm 249 610 559 498 381 356 Type 800 125 1016 965 38, 51 mm 249 660 610 498 457 406 This table summarizes span/pressure limitations for unreinforced duct. For larger duct sizes, see The Pocket Installer, AHS-3. SUSTAINABLE BUILDING ATTRIBUTES SUPERDUCT® RC COATED MAT-FACED FIBERGLASS DUCT BOARD WITH E3 PALLET ...The John's Manville Microlite Duct Wrap is an FSK foil back jacket with a Formaldehyde Free white Binder that cuts easily and without much dust. The 3/4 lb density is most common on HVAC ductwork, with R-4.2 achieved at 2" thickness, R6 at 2.13" thickness, R8 at 3" thickness, and R12 at 4″ thickness. Permeance Rating (Facing): 0.02.Jonathan Ive has 5,000 patents in his name By clicking "TRY IT", I agree to receive newsletters and promotions from Money and its partners. I agree to Money's Terms of Use and Priv...4NI-C. 4B. 4M. Designed for efficient installation and engineered to precise standards, our flexible duct sets the standard in quality and dependability. Unique to others in the industry, we manufacture flexible ductwork without the use of glues or adhesives. The mechanical-locked inner core maintains its shape at all 90° bends and offsets, t ...Type I, Unfaced Type III, FSK & PSK - White - ASTM C553 Type I, Type 75 Duct Wrap Type II, Type 100 & 150 Duct Wrap Type III, Type 150 Duct Wrap - ASTM C1136: FSK & White PSK Type II, Type IV Fire Safety Standards: - NFPA 90A, NFPA 90B FIRE RESISTANCE Fire Hazard Classification: - UL 723, ASTM E84, CAN/ULC-S102 Max. Flame Spread Index ...Factors that affect the prognosis for stage IV lymphoma include the specific type diagnosed, daily living routine, age, the level of lactate dehydrogenase in the blood, and the ext...Fire Barrier Duct Wraps. A key objective in advancing innovation for fire rated duct. wrap is to attain less thermal transfer (more fire resistance) in a lighter product. 3M has developed 3MTM Fire Barrier. Duct Wrap 615+ to be the only fire rated duct wrap. product you’ll need to help protect both grease ducts and.Ducts left unattended, created from an insufficient energy efficient home design or will become contaminated with harmful particulates Expert Advice On Improving Your Home Videos L...May 18, 2020 ... How to Install Duct Wrap on Air Duct Using Telescope Method 3M™ 615+. 2.7K views · 4 years ago ...more ...Hover Image to Zoom. $ 80 97. Pay $55.97 after $25 OFF your total qualifying purchase upon opening a new card. Apply for a Home Depot Consumer Card. R-6 insulation. Helps air duct system maintain a consistent air temperature. Easy installation for new and existing ductwork. View More Details. Unavailable at Moses Lake.Seal your piping with Orbit 2 in. x 50 ft. Pipe Wrap Tape. This PVC tape helps prevent corrosion and can be used with metal pipe or conduit in pressure-sensitive applications.Frost King. 12 in. x 15 ft. No Itch Duct Wrap Insulation R4. 88. (11) Questions & Answers (20) Hover Image to Zoom. $17.56. Enhances operating efficiency of duct installations.Cut SOFTR® Duct Wrap to "stretch-out" dimensions per Table 4. Then cut 2" (50mm) of insulation from the cut end and remove from the facing to form an overlapping staple/ tape fl ap, see Figure No. 1. Always install duct wrap with the facing toward the outside. Tightly butt the insulation seams together, see Figure No. 1.Duct Wrap. Microlite EQ FSK Formaldehyde-free duct wrap offers superior thermal performance and condensation control in a lightweight, blanket-type insulation with an FSK facing. It is recommended for HVAC system exteriors or surfaces where design parameters prohibit the use of liner or board. Installing contractors prefer Microlite EQ?s bio ...A. Before applying duct wrap, air ducts shall be clean, dry and tightly sealed at all joints and seams. B. All portions of duct designated to receive duct wrap shall be completely covered with duct wrap. C. To ensure installed thermal performance, duct wrap insulation shall be cut to "stretch-out" dimensions as shown in Table 2 below. D.Duct wrap, or ductwork insulation, is a cost-effective way to improve your home’s energy efficiency without replacing a functioning furnace or AC unit. For households looking for smart ways to lessen their environmental impact and lower their energy bill, ductwork insulation is an accessible and effective HVAC system upgrade.to the duct. C. 2 & 3 Sided Wrap Installation (Figure 4) When space does not allow for a complete wrap applied to the duct on all four sides, the DuctWrap XL is approved for 2 or 3 sided installations with mechanical attachment to a rated concrete or CMU assembly. (See Figure 4 for installation details.) D. Maa Aa M 1) Ba (F 1) - Minimum 1/2 ...The Fire Barrier Duct Wrap 615+ is a two layer flexible enclosure that can be used for one and two hour rated commercial grease ducts. Duct insulation is tested per ATSM E 2336 and is acceptable as an alternate to a shaft enclosure. The core insulation blanket is completely encapsulated in an aluminum foil fiberglass reinforced scrim covering..3M Fire Barrier Duct Wrap 20A is an ideal fire resistive enclosure for commercial kitchen grease ducts. It is a proven performance alternative to a. or 2 hour fire resistant rated shaft enclosures and provides zero clearance to combustible construction at overlap or collar. 3M Fire Barrier 1000 N/S, 1003 S/L or 2000+ Silicone Sealant is used in ...Uxcell Corrosion Protection Pipe Tape, 108 Ft x 2 Inch PVC Insulation Wrap Duct Tape Self Adhesive, White. Duck Brand 1.88 in. x 20 yd. Clear Transparent Duct Tape. In 100+ people's carts. Add $ 3 94. current price $3.94. 6.6 ¢/ft. Duck Brand 1.88 in. x 20 yd. Clear Transparent Duct Tape.Johns Manville Foil Faced Type 75 Duct Wrap with FSK Facing, 1-1/2 x 48 Inch x 100 ft, 0.75 lb Density, R4.2. Ready To Ship! 31 In Stock Now! Check Availability. Add to compare list. JM DUCTWRAP3. SKU: 56225 . Johns Manville Foil Faced Type 75 Duct Wrap with FSK Facing, 3 x 48 Inch x 50 ft, R8. Ready To Ship!and fastened with 4" (102 mm) to 6" (152 mm) nails or skewers placed 4" (102 mm) apart, or secured with a wire or banding system. Care must be taken to avoid damaging the duct wrap. Refer to diagram for staple stitching and butt-joint method. Installation Procedures Use the Application graphic to determine stretch-outs required for the nominalOverview. CertainTeed InsulPure Duct Wrap and WideWrap are top-tier insulation solutions for HVAC ductwork, providing superior thermal insulation and energy efficiency. They're easy to install and come in various sizes, backed by a strong warranty.Quiet Duct Wrap. Quiet-Duct Wrap is a lightweight, foil faced, fire retardant blanket-type insulation with multiple uses. The Duct-Wrap offers excellent thermal and acoustical performance and carries a Class-A Fire rating. Made from durable natural fibers, Quiet-Duct Wrap contains no fiberglass and does not itch or cause skin irritation.James Stahl, Jr. May 1, 2007. Firestopping non-dampered heating, ventilation, and air-conditioning (HVAC) duct penetrations in fire-rated walls is more involved than installing that ubiquitous red caulk into the space between the duct and the periphery of the opening. Because of the nature of thin sheet metal ductwork and the physics that come ... FRK Duct Wrap Insulation is ideal for cooling, heating orR value: R8.3. Thickness: 2-1/4 in. Width: 48 in. 0. Shop foJohns Manville Duct Wrap, Fbrgls 1-1/2"

Health Tips for Sks pwrnw

Pay $55.97 after $25 OFF your total qualifying purchase upon o.

CertainTeed InsulPure Duct Wrap and WideWrap are top-tier insulation solutions for HVAC ductwork, providing superior thermal insulation and energy efficiency. They're easy to install and come in various sizes, backed by a strong warranty. Benefits include energy savings through reduced heat loss and improved comfort, making them ideal for ...Inherent R-Values of Different Insulation Types. There is a typical inherent R-value per inch of an insulation material, which impacts how much you will need. For the most part, you have an expected range for the R-value of different insulating materials, as listed in the following table: Cellulose (loose-fill) R3.2-R3.8. Fiberglass (loose-fill ...What you absolutely need to know about the Sony a7 IV camera and why I, a person who tests gear all the time, ended up buying my own. Most photographers, professional or hobbyist, ...Utilizing Reflectix® to enhance the efficiency of your existing duct system is one of the "easiest to install" products you can select. There are no fibers or dust contained in the product, thus no need for respirators or protective garments. R-6.0 Note: Installation instructions and illustrated drawings are recommendations only, while ...Nov 27, 2023 · Insulation wrap, or faced microlite duct insulations, is like a superhero cape for your type duct HVAC system, swooping in with a vapor barrier seal to combat energy waste and blanket uneven indoor climates. Wrapping your ductwork in this thermal insulation protective layer, such as fiberglass duct wrap or single bubble insulation, is like ...Type II, Type 100 & 150 Duct Wrap Type III, Type 150 Duct Wrap - CAN/CGSB-51.11-92 - ASTM C1136: FSK & White PSK, Type II, Gray PSK, Type IV • Fire Safety Standards: - NFPA 90A, NFPA 90B Fire Resistance • Fire Hazard Classification: - UL 723, ASTM E84, CAN/ULC-S102 Max. Flame Spread Index: 25Nov 7, 2022 ... ... 4" driver Tape Measure As an Amazon Associate I earn from qualifying purchases ... Insulating round pipe elbows using fiberglass ductwrap ( ...Insera fire wraps. ₹ 200/ Square Meter Get Latest Price. Usage/Application: kitchen exhaust duct, partition walls of data centers and servers room, fire rated duct, tanks. Color: silver. Material: fire resistant with up to 120 minutes of fire resistance rating. Size: length 2 or 6 width 0.610 m. Density: 96. Country of Origin: Made in India.The cost to insulate 1,000 square feet of ductwork with duct wrap is between $2,250 and $2,500. Duct Board Insulation. ... Below are the installation costs per square foot for each major type of duct insulation material: Insulation Type Installation Cost per Square Foot; Duct Liner: $1.95 - $2.20 per sq. ft. Spray Foam: $1.15 - $3.50 per sq ...The Reflectix® Spiral Duct Insulation consists of 2 highly reflective layers of film (94%+ reflectivity). Two inner layers of insulating bubbles resist conductive heat flow while a center layer of polyethylene provides our product with high reliability and strength (nominal thickness 5/16 of an inch). Reflectix® Insulation is an ideal alternative to other types of fibrous insulation products ...Duct Wrap w/ FSK Type 75 (3/4 lb.) Duct Wrap w/ FSK Type 100 (1 lb.) Duct Wrap w/ FSK Type 150 (1-1/2lb.) Duct Wrap PSK White. Duct Wrap White Facing. Corporate Office .For heating and air conditioning ducts. Cushions and reduces vibrations. Can be tape securely in place. Stops vibration. Combines the properties of two popular insulating materials in one handy roll. It can be used on both heating and air-conditioning ducts, as well as on car and truck hoods and trunks.SOFTR® Duct Wrap is a blanket of glass fiber insulation factory-laminated to FRK vapor retarder facing. A 2" (50mm) stapling and taping flange is provided on one edge. This product is designed to meet existing performance standards such as NFPA 90A and 90B and other mechanical and energy codes. SOFTR® Duct Wrap FRK flexible design makes it ...Johns Manville. Duct Insulation Wrap, 25 ft L x 48 in W, Thickness 1 1/2 in, Fiberglass. Mfr # 670378. $84.15.butted tightly together and 6" (152.4mm) wide collar of duct wrap is centred over the joint, overlapping each blanket by 3" (75mm) minimum. 1. Single layer of 3M™ Fire Barrier Duct Wrap 615+ 2. Steel banding 1/2" (12.7mm) wide min. typical 3. 6" (152.4mm) min. wide 3M™ Fire Barrier Duct Wrap 615+ Collar 4. Tightly butted jointSOFTR® Duct Wrap shall be cut to "stretch-out" dimensions and 2" (50mm) piece of duct wrap removed from the facing at the end of the piece of duct wrap to form an overlapping staple and tape flap. Install duct wrap tightly butted with facing outside. Seams shall be stapled approximately 6" (150mm) on center with outward clinching staples.32.8 FTx 3 in Foiled Back Fiberglass Pipe Insulation Wrap,Pipe Insulation Foam Wrap Tape Ceramic Water Pipe Insulation Wrap for Outdoor Indoor Pipe Insulation Wrap Freezing Weather (1 Pack) 4.5 out of 5 stars 553M 615-PLUS-24 - 615+ 24" x 25 ft. Fire Barrier Duct Wrap- The 3M Fire Barrier Duct Wrap 615+ is a flexible fire-resistant wrap consisting of an inorganic fiber blanket encapsulated with a scrim-reinforced foil. It is used to fire rate commercial kitchen grease ducts as well as ventilation ducts. The 615+ duct wrap is a proven alternative to 1- or 2 …Jul 30, 2022 ... Shop Duct Insulation here: https://www.buyinsulationonline.co.uk/category/hvac-insulation/duct-insulation/ If you're looking for information ...The Insider Trading Activity of Foresite Capital Management IV, LLC on Markets Insider. Indices Commodities Currencies StocksDuct Wrap W/FSK Type 75 (3/4#) Duct Wrap W/FSK Type 100 (1#) Duct Wrap W/FSK Type 150 (1-1/2#) Duct Wrap PSK White; White Facing Duct Wrap; Mineral Wool Insulation.For duct wrap and duct liner applications, AEROFLEX® sheet & roll insulation can attenuate lower frequency HVAC noise (250 - 750 Hz) due to closed cell structure and density when compared to open-cell fibrous duct insulation. Additionally, it's always fiber-free, microbial-resistant and Indoor Advantage™ Gold Certified for low chemical ...A minimum 12-inch-long (305 mm) by .060-inch-thick (1.52 Nov 2, 2017 · Covers up to 60 sq. ft. of

Top Travel Destinations in 2024

Top Travel Destinations - Id: C1136 Type: II Id: C1290 Type: III Id: C553 Type: II (SOFTR Du

25. 50. When wet, coated surfaces of QuietR® Rotary Duct Liner in contact with galvanized steel may cause discoloration of the sheet metal. The surface burning characteristics of these products have been determined in accordance with UL 723 or CAN/ULC-S102. This standard should be used to measure and describe the properties of materials ...32.8 FTx 3 in Foiled Back Fiberglass Pipe Insulation Wrap,Pipe Insulation Foam Wrap Tape Ceramic Water Pipe Insulation Wrap for Outdoor Indoor Pipe Insulation Wrap Freezing Weather (1 Pack) 4.5 out of 5 stars 55Duct wrap is applied to the outside of a sheet metal duct. It is blanket-style insulation that wraps around the duct.Certified shaft alternative 1- and 2-hour fire-rated duct wrap. 3M Fire Barrier Duct Wrap 615+ is a fire wrap certified for grease ducts to ASTM E 2336 (including ASTM E119 engulfment) in 2-layer systems. Certified for ventilation ducts to ISO 6944 in 1-layer systems and for other key life safety duct applications.Scoot back the duct insulation to expose pipe joints, clean any dust or oils, then seal with a liberal coat of mastic. The blue low tack painter's tape was helpful for holding back the insulation: Seal the Sheet Metal Duct Pipe with Mastic. Mastic is applied to all duct pipe joints and over the sheet metal screws for an air tight seal.It is a proven alternative to 1- and 2-hour fire resistant shaft enclosures for grease ducts. 3M™ Fire Barrier Duct Wrap 615+ performs in temperatures up to 2192F/1200C.3M™ Fire Barrier Duct Wrap 615+ is the only fire-rated duct wrap product you#39;ll ever need to help protect both grease ducts and air ducts while passing the necessary fire ...Type I – Fiberglas™ Duct Wrap Type 75; Type II – SOFTR ® Duct Wrap FRK Types 100 and 150. (Operating temperatures to 250°F (121°C) and thermal values to 150°F (66°C) mean.) 1 Preferred specification is ASTM Type 75C1290. SOFTR® Duct Wrap is a blanket of glass fiber insulation factory-laminated to FRK vapor retarder …This alumaguard duct wrap can be used in applications from as low as -20°F to temperatures as high as 150°F. 8.5 mils thick and 30% stronger than the competition. This insulation cladding functions as a non-permeable vapor barrier - assures integrity of the insulation system. Exceeds UL 723 requirements for Flame Spread and Smoke Developed ...A. Construct the ventilation duct using sections affixed to each other with seams or flanges. B. Reinforce the ventilation duct to IMC, SMACNA* or NFPA 90A requirements designed to carry the weight of the ventilation duct assembly covered with insulation (Item 4) under a fire load equivalent to ASTM E 119 time- temperature curve.C403.2.9 - Duct and Plenum Insulation & Sealing 1 "Supply and return air ducts and plenums shall be insulated with a minimum of R-6 insulation where located in unconditioned spaces and where located outside the building with a minimum of R-8 insulation in climate zones 1-4 and a minimum of R-12 insulation in climate zones 5-8.Just like the duct wrap materials, there are a wide variety of jacketing options to meet project requirements. There are the “traditional”: metal jacketing, PVC and mastic, and mesh. For some applications the …4) in place without cutting or damaging the insulation (Item 4) or ventilation duct (Item 1). 4. CERTIFIED MANUFACTURER: 3M Company CERTIFIED PRODUCT: 3M Fire Barrier™ Duct Wrap MODEL: 15A, 615 INSULATION: For 15A - Apply one layer of nominal 1-1/2-inch-thick 8-pcf blanket, made of mineral wool fibers and fiberglass,Fire-rated duct wrap consisting of an inorganic fiber blanket encapsulated with a scrim-reinforced foil; Blanket is adhered to the foil scrim it will resist wrapping and slumping ; Third party certified to ASTM E2336 (grease duct test standard) and ISO 6944 (air duct test standard) Tested and listed with UL and intertek, meets IBC, IMC, UMN, NFPA and …4-Hour Fire Rated Duct. DuraDuct™ 4HR is the only 4-hour fire rated duct system on the market. DuraDuct™ 4HR is a single source 4-hour fire rated, zero clearance ventilation duct system ideal for applications when the highest degree of fire protection is required. The DuraDuct ™ 4HR provides the flexibility you need to get the job done right.Microlite® XG™ Formaldehyde-free™ duct wrap insulation is a light weight, highly resilient, blanket-type thermal and acoustical insulation made of glass fibers, bonded with a white, formaldehyde-free resin. Microlite XG Formaldehyde-free™ insulation is available in a variety of densities, thicknesses, widths and roll lengths. It is ...InsulPure Duct Wrap and WideWrap are suitable for use with most heating, ventilating and air-conditioning ductwork operating at temperatures from 35°F to 250°F (1.7°C to 121°C) for faced InsulPure Duct Wrap and WideWrap and from 35°F to 450°F (1.7°C to 232°C) for unfaced. INSTALLATION.Uninsulated or poorly insulated ducts in unconditioned spaces cause both discomfort and high energy bills. Get smarter about the spaces that aren't currently protected and see how thermal and acoustic performances improve. Duct insulation (or duct wrap) ensures less strain on HVAC systems and positively impacts energy costs.It is a proven alternative to 1- and 2-hour fire resistant shaft enclosures for grease ducts. 3M™ Fire Barrier Duct Wrap 615+ performs in temperatures up to 2192F/1200C.3M™ Fire Barrier Duct Wrap 615+ is the only fire-rated duct wrap product you#39;ll ever need to help protect both grease ducts and air ducts while passing the necessary fire ...Frost King® Duct Wrap Combines the properties of two popular insulating materials in one handy roll. Use on both heating and air-conditioning ducts.Johns Manville. Duct Insulation Wrap, 25 ft L x 48 in W, Thickness 1 1/2 in, Fiberglass. Mfr # 670378. $84.15.MATERIAL SAFETY DATA SHEET 3M Fire Barrier - Duct Wrap 15A, 20A; Plenum Wrap 5A; and Collar 20A 01/31/2008 Page 4 of 6 Specific Gravity 2.5 - 3.0 [Ref Std: WATER=1] Melting point Not Applicable Solubility in Water Negligible Volatile Organic Compounds 0 % weight Percent volatile 0 % VOC Less H2O & Exempt Solvents 0 g/l SECTION 10: STABILITY AND REACTIVITYjm duct wrap type-75 fsk (r= 4.2) 1.5"x 48"x 100' (4 rl/pk) 21a01jm101000: jm duct wrap type-75 fsk (r= 5.6) 2.0"x 48"x 75' (4 rl/pk) 21a01jm101006: jm duct wrap type-75 fsk (r= 6.0) 2-1/5"x 48"x 75' (4 rl/pk) 21a01jm101002: jm duct wrap type-75 fsk (r= 8.3) 3.0"x 48"x 50' (4 rl/pk) 21a0101001: jm duct wrap type-75 fsk (r=12) 4.4"x48"x45' (4 rl ...Trymer® 25-50 PIR 4 800 Series Spin-Glas® 4 1000 Series Spin-Glas® 4 Precipitator Spin-Glas® 5 XSPECT® ISOfoam APF Board 5 Micro-Flex ® 6 HTB 26 Spin-Glas® 6 Microlite ® FSK Duct Wrap 6 Microlite ® PSK Duct Wrap 7 Incombustible Hullboard 7 Incombustible Microlite® 7Formaldehyde-free™ Fiberglass Duct Wrap HVAC Insulation Version 2.2 Revision Date 01/25/2021 Print Date 01/25/2021 2 / 6 US/EN In case of skin contact : Take off all contaminated clothing immediately. If on skin, rinse well with water. Get medical attention if irritation develops and persists. Wash contaminated clothing before re -use. Knauf Insulation External Duct wrap (faced) with ECOSE